Industrial Photobioreactors Algae Production Fermentor Bioreactor For Algae Photobioreactor Plant Photo Fermenter

Product Description

Plant Cell Illumination Bioreactor Overview
Illumination Bioreactor Control Panel
Product Description
Bioreactor Vessel Chamber
Bioreactor Light Intensity Adjustment
Plant Cell Illumination Bioreactor Cell Culture Bioreactors
Plant cell illumination bioreactor suitable for microbial cultures with low shear force. Internal or external light sources with adjustable intensity can be provided.
  • The culture of marine organisms, especially the cells and tissues of microalgae and macroalgae, is a research focus all over the world. Among them, some secondary metabolites such as marine terpenoids are widely studied secondary metabolites.
  • The photobioreactor is suitable for culture of algae cells and tissues. It adopts a long and narrow tank with a total volume of 3.6L and tank cover specification of 11 SNW. It is provided with specially designed low position cooling jacket and outer casing type light source to ensure the transmission effect of lighting. It has various types of mixing paddles for selection such as flat paddle, bevel paddle and turbine paddle. The light intensity can be adjusted freely according to the percentage, it can simulate various lighting modes, such as day and night alternation.
  • Technical parameters: three fluorescent lamps (8W) are provided as standard configuration, or products can be customized according to customer requirements. The light intensity is adjustable.
Siemens PLC Control Screen Interface
Peristaltic Pumps Integration
  • Siemens PLC control system + vinylon LCD touch screen, is used to display all measured values and control parameters, which greatly facilitates the user's operation. you can use USB for data transmission, sampling and displaying tank data, browsing and analyzing system data, reading settings.
  • Each tank is equipped with 4 peristaltic pumps beside the front tank, which can supply acid, alkali, defoamer and culture medium to the fermentation tank.
  • Various parameters in fermentation such as pH, DO, temperature and speed can be monitored by the controller, and all data and control parameters can be transmitted to the controller or computer.
  • The structure is compact, and various components can be integrated into the fermentation system.
  • Using off-position sterilization magnetic stirring method, which has a simple structure and stable operation.
Technical Specifications
Model LBR-GCL Series
Volume customization
Diameter to height ratio 1:2~2.5
Feeding volume 70%
Material Stainless steel 304/316
Tank Pressure manual adjustment, pressure gauge display; range: 0~0.20Map;
Sterilization method Automatic or manual sterilization
Foam control electrode detection, peristaltic pump replenishing
Stirring Speed 50~700rpm stepless speed; accuracy: ±1rpm
pH detection range: 2~12ph; control accuracy: ±0.02ph, resolution: 0.01ph;
DO detection range: 0~100%, control accuracy: ±3%; resolution: 0.1%;
Ventilation manual adjustment, flow meter display;
Application Fields
Microbial Fermentation Application
Microbial Fermentation
Biopharmaceuticals Application
Biopharmaceuticals
Tissue Engineering Application
Tissue Engineering
Algal Biotechnology Application
Algal Biotechnology
Agricultural Biotechnology Application
Agricultural Biotechnology
Biofuels and Renewable Energy Application
Biofuels and Renewable Energy
Product Showcase
Bioreactor Assembly View 1
Bioreactor Assembly View 2
Inner Tank and Agitator System
Sensors and Connectors
Upper Tank Cover Valves
Control Mainframe Connection
Double Layer Glass Design
Complete Setup View
Control System Testing
Auxiliary Pumps Close-up
Frequently Asked Questions
What types of cultures are suitable for this illumination bioreactor?
This photobioreactor is specifically designed for microbial cultures requiring low shear force, and it is highly suitable for cultivating the cells and tissues of marine organisms, microalgae, and macroalgae.
How is the light intensity adjusted and controlled in the system?
The light intensity can be adjusted freely based on percentages. The system can simulate various lighting modes, such as day and night alternation, to accommodate different cellular growth requirements.
What control system does the bioreactor use?
The bioreactor utilizes a Siemens PLC control system combined with a Vinylon LCD touch screen, allowing for simple displays of measured values, system analytics, setting configurations, and convenient USB data transmission.
Which parameters are monitored during the fermentation process?
Key fermentation parameters such as pH value, Dissolved Oxygen (DO), temperature, and stirring speed are continually monitored by the controller, and all data can be easily transmitted to a computer.
What type of stirring mechanism does this equipment employ?
The equipment employs an off-position sterilization magnetic stirring method, which features a simple mechanical structure and ensures highly stable operation.
What is the standard volume and customization option for the bioreactor?
The standard tank configuration has a total volume of 3.6L with a narrow design for optimal light transmission, but customizable volumes and specifications can be provided to meet specific research requirements.

Related Products